Interruttore di prossimità - Ferroso " Serie FS-B

Proximity Switch - Radiation Resistant - High Temperature - Harsh Nuclear Environment non-LOCA
Certifications / Approvals
As per product features list.
Dry Contact SPCO / SPDT (Form C) | PEEK Leads | 316L Stainless Steel
This nuclear proximity switch is manufactured with a Stainless steel 316L housing, and is provided with PEEK Leads for use in Harsh nuclear environments inside or outside containment Non LOCA. It exceeds Global Environmental Non-LOCA and Post Fukushima Seismic requirements at 10G RIM, and is capable of operating between -40°C and 204°C with allowable excursion peak to 260°C /500°F maximum temperature.
Being a non-contact proximity sensor it requires the use of EuroSwitch Nuclear Target Magnetic Actuators to operate reliably. Once set, it does not wear or need readjustment during its life time in numerous applications around the Nuclear Power Plant.
It has volt free, silver-palladium contacts in SPCO / SPDT (Form C) arrangement, and is capable of switching up to 4A at AC or DC voltages from 6V up to 240V, and is reliable through millions of operations.
Adatti alla progettazione di funzioni di sicurezza fino a SIL3, questi interruttori di prossimità soddisfano i requisiti della norma IEC 61508:2010 Percorsi 1H e 1S con capacità sistematica (SC3) come elemento/sottosistema adatto all'uso in sistemi di sicurezza che eseguono funzioni di sicurezza fino a SIL 3 incluso con HFT =1 (1oo2).
- Forma del corpo
- Cilindrico
- Materiale del corpo
- Acciaio inossidabile 316L
- Modalità di contatto
- SPCO / SPDT (Modulo C)
- Materiale di contatto
- Palladio-Argento
- Filettatura di montaggio
- 5/8"-18 UNF (lunghezza 47,75mm / 1,88") c/w 2 x controdadi di bloccaggio
- Corrente massima
- 4A
- Collegamento
- PEEK conduttori
- Entrata del condotto
- 1/2" NPT
- Disdetta
- Fili di piombo
- Temperatura di esercizio
- -40°C to +204°C (260°C Peak) / -40°F to +400°F (500°F Peak)
- Campo di rilevamento con magnete
- <12mm (0.47")
- Valutazione della pressione nominale di rilevamento
- 2000psi / 138 bar
- Protezione dell'ambiente
- IP 66, 67 e 68 (24 ore a 30 m) / NEMA 4X e 6P
- Valutazione di sicurezza
- SIL 2 / SC3
- Ripetibilità
- Circa 0,05 mm (0,002")
- Tempo di risposta
- 8 ms
- Differenziale / Isteresi
- < 0.51mm (0.020")
- Radiation Resistance
- 540kGy (54 MRad) gamma
- Seismic
- Exceeds Global Environmental Non-LOCA and Post Fukushima Seismic requirements 10G RIM
- Vibration Resistance
- 10g RMS
Tutti i nostri prodotti sono disponibili anche come Sede Ordinaria / Generale Industriale.
| Documento | Lingua |
|---|---|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
| Istruzioni per l'installazione e il funzionamento |
|
Versioni alternative disponibili
| Caratteristica | Variazione | Pagina dei prodotti correlati |
|---|