Näherungsschalter- Magnetisch
Explosion Proof & Intrinsically Safe Proximity/Limit Switches SPDT/SPCO
Zertifizierungen / Genehmigungen







Dokumente, die angezeigt/heruntergeladen werden sollen
Series Overview - 316 Stainless Steel Prox Switch with Multi Voltage Capability
The ES-14 Series Proximity Switch is highly adaptable and can be used in a multitude of applications where a reliable signal is required.
Volt free SPCO/SPDT (Form C) contacts as standard with the ability to use as Normally Open or Normally Closed devices. The ES-14 series offers versatility and multi-voltage flexibility by being able to switch either DC or AC at up to 240V.
The mounting thread is M12x1.0 UNF. It is available hardwired with a range of cable and lead types to suit the application.
The standard electrical conduit connection is M20x1.5 with an 1/2"-14 NPT imperial option also available.
The presence of an external magnetic actuator is required for operation. Designed for end sensing. Sensing ranges are dependent on the magnetic actuators used.
The ES-14 Series is covered by the following hazardous area certifications.
Explosion Proof: | IECEx & ATEX Ex d/db/tb (Zone 1 & Zone 21) ¦ UL/CSA (Class I & II Div1 & Div2) |
Intrinsically Safe: | IECEx & ATEX Ex ia (Zone 0 & Zone 20) ¦ UL/CSA IS (Zone 0) |
Other Regional Approvals Include: | EAC/TRCU, INMETRO, KCs, CCOE/PESO, ECAS ex, NEPSI/CQST |
The ES-14 series proximity switches meet the requirements of IEC 61508:2010 Routes 1H & 1S with Systematic Capability (SC3) as an element/subsystem, and are suitable for use in safety related systems performing safety functions up to and including SIL 2 with HFT=0 (1oo1) and SIL 3 with HFT =1 (1oo2).
- Gehäuseform
- Zylinderförmig
- Gehäusematerial
- Edelstahl 316L
- Kontaktmaterial
- Rhodium (Wolfram optional)
- Anschraubgewinde
- M12x1.0 (39.37mm / 1.55" long) c/w 2 x locknuts
- Strom max.
- 830mA
- Kabeleinführung
- M20 x 1,5
- Temperaturklasse (T-Einstufung)
- T4 / T6
- Erfassungsbereich mit Magnet
- Bis zum Maximum in der Magnettabelle
- Druckbelastung der Erfassungsfläche
- 2.000 psi/ 138 bar
- Umweltschutz
- IP 66, 67 & 68 (24hrs at 30m)/ NEMA 4, 4X, 6 & 6P
- Sicherheitsbewertung
- SIL 2 / SC3
- Actuation
- Magnetically
Alle unsere Produkte sind auch als „Gewöhnlicher Standort“ und als „Allgemein industriell“ erhältlich.
Bitte wählen Sie Ihr Zertifizierungs- und Schutzkonzept für Ihre spezifische Anforderung aus dem folgenden Teilenummer-Ersteller aus
Document | Language |
---|---|
Installation and Operating Instructions | ![]() |