SB Range » SB-XP2 Series

Explosion Proof - SwitchBox - ATEX/IECEx/UKEx; Ex db IIC T6/T5/T4 Gb; Ex tb IIIC T85C/T100C/T135C Db; UL/CSA Cl I, Div 1 Grps B,C,D; Cl II, Div 1 Grps E,F,G; Cl III, Div 1
Switchbox material - Aluminium Alloy <0.4% Cu, Polyester coated, Switch type - SPDT Mechanical switches with Silver contacts, Conduit entry - 3/4" NPT x 4, Drive type - VDI/VDE Namur Rotary
- Enclosure Type
- XP2
- Enclosure Material (SB)
- Aluminium Alloy <0.4% Cu, Polyester coated
- Enclosure Certification
- ATEX/IECEx/UKEx; Ex db IIC T6/T5/T4 Gb; Ex tb IIIC T85C/T100C/T135C Db; UL/CSA Cl I, Div 1 Grps B,C,D; Cl II, Div 1 Grps E,F,G; Cl III, Div 1
- Transmitter
- No Transmitter fitted
- Switch Ratings
- 125/240VAC 10A; 36VDC 10A
- Switch Type
- SPDT Mechanical switches with Silver contacts
- Number of Switches
- 4
- Temperature Range
- Enclosure Ambient: -50 to +95C Certification limitations apply
- Indicator
- Colour - Open - BLACK / Closed - YELLOW
- Terminal Options
- Terminal Block Screw clamp 10 way with solenoid backwire facility
- Conduit Entry
- 3/4" NPT x 4
- Hazardous Location
- II 2 GD, Zone 1, 2, 21, 22; Class I, II, III Div 1
- Temperature Class (T Rating)
- T4/T5/T6
- Gas Group
- IIC, Class I, Div 1 Groups B C D
- Dust Group
- IIIC: Class II Div 1 Grps E F G; Class III Div 1
- Drive type
- VDI/VDE Namur Rotary
- Mounting
- F05 M6 x 11 deep 35.36 Sq - 5/16 UNC x 11 deep 57.20 Sq
- Environmental protection
- IP66/IP67; Nema 4,4X
- Shaft material
- 316 Stainless Steel
- Fastener material
- 316 Stainless Steel
All of our products are also available as Ordinary Location / General Industrial.