Proximity Switch - Ferrous
Bi-Colour LED Indication Proximity Switch
Documents to view/download
Series Overview
The FS-GM Series Proximity Switch (M18x1.0 Thread) is highly versatile and can be used in a multitude of applications where LED indication and a reliable signal is required. Utilising proven magnetic technology enables them to sense ferrous material, such as carbon steel or stainless steel (17/4 or 400 series) at up to 2.5mm (0.1"). Volt free SPCO/SPDT (Form C) contacts as standard with the ability to use as Normally Open or Normally Closed devices.
The FS-GM Series is available either hardwired or with V3 Mini-Change Quick Disconnect connectors.
The FS-GM Series is covered by the following hazardous area certifications.
Intrinsically Safe: | IECEx & ATEX Ex ia (Zone 0 & Zone 20) ¦ UL/CSA IS (Zone 0) |
The FS-GI series proximity switches meet the requirements of IEC 61508:2010 Routes 1H & 1S with Systematic Capability (SC3) as an element/subsystem, and are suitable for use in safety-related systems performing safety functions up to and including SIL 2 with HFT=0 (1oo1) and SIL 3 with HFT =1 (1oo2).
- Body Shape
- Cylindrical with LED Indication
- Contact Arrangement
- SPCO / SPDT (Form C)
- Contact Material
- Palladium-Silver
- Max Current
- 250mA
- Conduit Entry
- M20 x 1.5
- Termination
- Cabled
- Temperature Class (T Rating)
- T6
- Operating Temperature
- -40°C to +60°C / -40°F to +140°F
- Sensing Face Pressure Rating
- 2000psi / 138 bar
- Environmental Protection
- IP 66, 67 & 68 / NEMA 4, 4X, 6 & 6P
- Safety Rating
- SIL 2 / SC3
- Mounting Thread
- M18x1.0 (47.75mm / 1.88" long)
- Sensing Range with Magnet
- <12mm (0.47")
- Range (ferrous target)
- 2.5mm|0.10"
- Repeatability
- Approx. 0.05mm (0.002")
- Response Time
- 8 ms
- Differential / Hysteresis
- < 0.51mm (0.020")
IEC 61508:2010; SC3 ¦ SIL 2 with HFT=0 (1oo1) and SIL 3 with HFT =1 (1oo2)
All of our products are also available as Ordinary Location / General Industrial.
Please select your certification and protection concept for your specific requirement from the Part Number builder below