ES Range

Proximity/Limit Switch for General Industrial Use
Certifications / Approvals




ES-46 Series Overview
The ES-46 Series Magnetic Proximity Switch has a 316 Stainless Steel Rectangular Housing with volt free contacts. It has a maximum switching current of 830mA. It requires the use of a magnetic target to operate.
Suitable for use in the design of safety functions up to SIL2 or SIL3.
Using the latest production methods and materials this product meets global certification requirements and its robust design makes it suitable for use in arduous and hazardous environments.
Euroswitch products are also available with multi-approvals including combinations of the following global and regional certification standards. The ES-46 Series is covered by the following hazardous area certifications.
| Explosion Proof: | IECEx & ATEX Ex d db tb (Zone 1 & 2 and Zone 21 & 22) UL/CSA Class I, Class II and Class III, Division 1 & Division 2 (Cl1 Div1 ; Cl2 Div1 ; Cl1 Div 2 ; Cl2 Div2) |
| Intrinsically Safe: | IECEx & ATEX Ex ia (Zone 0 & Zone 20) ¦ UL/CSA IS (Zone 0) |
| Other Regional Approvals Include: | EAC TRCU, INMETRO, KCs (KOSHA), PESO CCOE , ECAS ex, NEPSI CQST |
The ES-46 series proximity switches meet the requirements of IEC 61508:2010 Routes 1H & 1S with Systematic Capability (SC3) as an element/subsystem, and are suitable for use in safety related systems performing safety functions up to and including SIL 2 with HFT=0 (1oo1) and SIL 3 with HFT =1 (1oo2).
- Housing Type
- Rectangular with Cable
- Housing Material
- 316L Stainless Steel
- Contact Arrangement
- NO / SPST (Form A)
- Contact Material
- Rhodium (Tungsten optional)
- Dimensions
- 35mm x 13mm x 16mm c/w fixing screws
- Maximum Current
- 830mA
- Operating Temperature Range
- -60°C to +204°C / -76°F to +400°F
- Sensing Range with Magnet
- Up to the maximum in the magnet table
- Sensing Face Pressure Rating
- 2,000psi / 138 bar
- Environmental protection
- IP 66, 67 & 68 (24hrs at 30m)/ NEMA 4X & 6P
- Safety Rating
- SIL 2 / SC3
- Actuation
- Magnetically Actuated
All of our products are also available as Ordinary Location / General Industrial.
Please select your certification and protection concept for your specific requirement from the Part Number builder below
| Document | Language |
|---|---|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|
| Installation and Operating Instructions |
|