Vibration Sensors » VSE-A Series
Vibration Sensor - UL & CSA Class I II III Div 2, Zone 2 Grps Grps A B C D / Grps F G T4A - Integral Junction Box - 316L Stainless Steel
Vibration Sensor Certified for UL & CSA Class I II III Div 2, Zone 2 Groups Grps A B C D / Grps F G T4A Rated for use in Gas & Dust Class I II III Div 2
The Vibration Sensor series of vibration sensors provide measurement of overall vibration levels being generated by all types of rotating machinery in Hazardous Areas, and can be directly connected to PLC, DCS and other industrial controllers.
The Vibration Sensor type are loop powered, 4-20mA output vibration sensors configured with a full scale acceleration output (RMS or Peak) of between 5g to 50g. The housing is manufactured from 316 stainless steel, and it is provided with a fully potted cable suitable for use in hazardous environments.
Benefiting from state-of-the-art annular shear design, our Vibration Sensor series sensors provide better frequency response, improved base strain, lower noise, and an insensitivity to cable motion compared to the market competition.
It is available certified for Hazardous Area use including ATEX / IECEx / UL / CSA / TRCU & INMETRO.
- Body Shape
- Field Wireable Connection Head - Side Entry
- Body Material
- 316L Stainless Steel
- Conduit Entry
- M20 x 1.5
- Mounting Thread
- M6x1.0 (c/w mounting stud)
- Sensing Element Type
- Piezoelectric Annular Shear
- Output
- Acceleration
- Output Type
- IEPE/ICP® Voltage (4mA Constant Current Supply)
- Sensitivity
- 50 mV/g (high to medium frequency)
- Frequency Response
- 1 to 11,000 Hz ±10% | (0.5 to 16,000 Hz ±3 dB)
- Vibration Limit (Continuous)
- 160g
- Shock Limit
- 5000g
- Linearity
- ±1% max
- Certification & Approvals
- UL & CSA (Underwriters Laboratory & Canadian Standards Association)
- Hazardous Location
- Class I II III Div 2
- Gas Group
- Grps A B C D
- Dust Group
- Grps F G
- Temperature Class (T Rating)
- T4A
- Operating Temperature
- -20ºC to +70ºC
- ESD Protections
- > 40V
- Environmental Protection
- IP 66, 67 & 68 (24hrs at 30m)/ NEMA 4X & 6P
- Power Requirements
- Constant current +2 to +10mA (+22 to +28 VDC)
- Grounding
- Isolated from machine ground
- Shielding
- Internal Faraday Shielding
- Protection
- Overvoltage and Reverse Polarity
- Mass
- 450g
All of our products are also available as Ordinary Location / General Industrial.